Description
Closed loop
Industrial applications, voltage measuring of all waveforms AC, DC
- Chassis mount
- Closed loop (compensated)
- High dielectric strength
- Precise linearity
- Precise accuracy
- High dynamic response
- No foucault losses in the magnetic circuit
- EMC shielding (optional)
Electrical specifications
Primary nominal RMS voltage | VPN | 950 A |
Primary voltage measuring range | VP | ± 4000 A |
Output measuring resistance | RM | 220 Ω max for 1400 V @ 24 V 70 °C |
Secondary nominal RMS curent | ISN | 50 mA for 1000 V |
Conversion ratio | KN | 1000 V / 50 mA |
Auxiliary supply voltage | VC | ±15 to ±24 VDC ±5 % |
Current consumption | IC | ±33 mA + Is @ 24 VDC |
Dielectric strength between: | ||
primary and secondary circuit | VD1 | 6 kV – 50 Hz – 1 min |
shield and secondary circuit | VD2 | 1.5 kV – 50 Hz – 1 min |
Overall accuracy @ IPN – TA = 25 °C | XG | ± 0.7 % |
Linearity | EL | < 0.1 % |
Offset current @ IP = 0 – TA = 25 °C | I0 | ± 0.2 mA max |
Thermal drift of I0 between -40 °C…+85 °C | I0T | ± 1 mA max |
Resp.time @ 90% of VPN | Tr | < 100 µs |
Frequency bandwidth (-3 dB) | f | DC to 100 kHz by technology |
General specifications
Operating temperature | TA | -50 °C…+85 °C |
Storing temperature | Ts | -50 °C…+90 °C |
Secondary coil resistance @ 70 °C | Rs | 60 Ω ± 7%C |
Weight | m | 500 g ± 5% |
Standards
EN 50155
IEC 61373
NF F16-101/102
IEC 60068-2-11