MSV 100 – 950 V

Description

Closed loop

Industrial applications, voltage measuring of all waveforms AC, DC

  • Chassis mount
  • Closed loop (compensated)
  • High dielectric strength
  • Precise linearity
  • Precise accuracy
  • High dynamic response
  • No foucault losses in the magnetic circuit
  • EMC shielding (optional)

Electrical specifications

Primary nominal RMS voltage VPN 950 A
Primary voltage measuring range VP ± 4000 A
Output measuring resistance RM 220 Ω max for 1400 V @ 24 V 70 °C
Secondary nominal RMS curent ISN 50 mA for 1000 V
Conversion ratio KN 1000 V / 50 mA
Auxiliary supply voltage VC ±15 to ±24 VDC ±5 %
Current consumption IC ±33 mA + Is @ 24 VDC
Dielectric strength between:
   primary and secondary circuit VD1 6 kV – 50 Hz – 1 min
   shield and secondary circuit VD2 1.5 kV – 50 Hz – 1 min

 

Overall accuracy @ IPN – TA = 25 °C XG ± 0.7 %
Linearity EL < 0.1 %
Offset current @ IP = 0 – TA = 25 °C I0 ± 0.2 mA max
Thermal drift of I0 between -40 °C…+85 °C I0T ± 1 mA max
Resp.time @ 90% of VPN Tr < 100 µs
Frequency bandwidth (-3 dB) f DC to 100 kHz by technology

General specifications

Operating temperature TA -50 °C…+85 °C
Storing temperature Ts -50 °C…+90 °C
Secondary coil resistance @ 70 °C Rs 60 Ω ± 7%C
Weight m 500 g ± 5%

Standards

EN 50155

IEC 61373

NF F16-101/102

IEC 60068-2-11

    + Inquiry form