Description
Closed loop
Industrial applications, current measuring of all waveforms AC, DC.
- Chassis mount
- Closed loop
- High dielectric strength
- Precise linearity
- Precise accuracy
- High dynamic response
- No foucault losses in the magnetic circuit
Electrical specifications
Primary nominal RMS voltage | VPN | 2000 A |
Primary voltage measuring range | VP | ± 3000 A |
Output measuring resistance | RM | 11 Ω max @ 24 V 70 °C |
Secondary nominal RMS curent | ISN | 400 mA |
Conversion ratio | KN | 1:5000 |
Auxiliary supply voltage | VC | ±15 to ±24 VDC ±5 % |
Current consumption | IC | ±22 mA + Is @ 15 VDC |
Dielectric strength between: | ||
primary and secondary circuit | VD1 | 6 kV – 50 Hz – 1 min |
Overall accuracy @ IPN – TA = 25 °C | XG | ± 0.7 % |
Overall accuracy @ IPN – TA = -40 °C…85 °C | XG | ± 1 % |
Linearity | EL | < 0.1 % |
Offset current @ IP = 0 – TA = 25 °C | I0 | ± 0.25 mA max |
Thermal drift of I0 between -40 °C…+85 °C | I0T | ± 1 mA max |
Resp.time @ 90% of IPN and di/dt 100 A / µs | Tr | < 100 µs |
di/dt accuracy followed | di/dt | > 100 A / µs |
Frequency bandwidth (-3 dB) | f | DC to 100 kHz by technology |
General specifications
Operating temperature | TA | -40 °C…+85 °C |
Storing temperature | Ts | -50 °C…+90 °C |
Secondary coil resistance @ 70 °C | Rs | 25 Ω |
Weight | m | 1550 g ± 5% |
Standards
EN 50178
EN 61000-6-2
EN 61000-6-4