Rolling stock

  • TELAU 400 relay – Delay-on pull-in or drop-out, 4 C/O

    The TELAU 400 is a delay-on pull-in or drop-out relay with 4 double make / double break C/O contacts (form Z). The delay is fully programmable with a dip switch from 0.25 hours to 255 hours. The access to dip switch is available by removing time delay cover. This feature prohibits frivolous field time delay setting. The plug-in design offers secure locking feature for maximum ease of maintenance (no wires…
  • TFBBU 400 relay – Flip flop, 4 contacts

    The TFBBU 400 is a flip flop relay with 4 double make / double break C/O contacts (form Z). The transient pull-in mode or dropout delay is fully programmable with a dip switch and activates or deactivates the relay. The access to dip switch is available by removing time delay cover. This feature prohibits frivolous field time delay setting. Function can be also be factory set on order. The plug-in…
  • THBBU 400 relay – Priority, delay on pull-in

    The THBBU 400 is a pull-in and drop-out relay which can be directly pull-in by “0V” on d3 pin. This command is priority on relay pull-in. It is equipped with 4 double make / double break C/O contacts (form Z). The relay is fully programmable with a dip switch for time setting. The access to dip switch is available by removing time delay cover. This feature prohibits frivolous field time…
  • Touch protection for covering free busbar connectors

    Yellow (RAL 1004), packed per 1 Set of 5 caps. Ordering code: 631910000
  • TPBAU 400 relay – One-shot time delay

    The TPBAU 400 is a one-shot on pull-in or drop-out relay with 4 double make / double break C/O contacts (form Z). The delay is triggered by the up front of the command input and is fully programmable with a dip switch from 0.25 s to 63 min. The access to dip switch is available by removing time delay cover. This feature prohibits frivolous field time delay setting. The plug-in…
  • TPBAUN 400 relay – One-shot time delay with negative edge command

    The TPBAUN 400 is a one-shot on pull-in or drop-out relay with 4 double make / double break C/O contacts (form Z). The delay is triggered by the negative edge of the command input and is fully programmable with a dip switch from 0.25 s to 63 min. The access to dip switch is available by removing time delay cover. This feature prohibits frivolous field time delay setting. The plug-in…
  • TPBBU 400 relay – One-shot time

    The TPBBU 400 is one-shot time on pull-in or drop-out relay with 4 double make / double break C/O contacts (form Z). The delay is triggered by the up front of the command input and is fully programmable with a dip switch from 0.25 s to 63 min. The access to dip switch is available by removing time delay cover. This feature prohibits frivolous field time delay setting. The plug-in…
  • TPWS Control Unit

    As Network Rail prepares to rollout ETCS across its network, work is also starting to deliver rolling  stock that is compatible with the new system. All  new trains currently on order for the UK will be ETCS-ready, and the initial steps to upgrade some existing fleets have been taken. (more…)
  • TTBCA 200 relay – Delay-on pull-in, instantaneous

    This time delay relay has 2 change over simple break contacts with 1 instantaneous contacts and 1 delayed contacts on pull-in fully programmable (with dipswitch) from 0.5 seconds to 4 seconds. The access to dip switch is available by removing time delay cover. This feature prohibits frivolous field time delay setting. The plug-in design offers secure locking feature for maximum ease of maintenance (no wires need to be disconnected or…
  • TTBCA 400 relay – Delay-on pull-in, instantaneous

    This time delay relay has 4 changeover simple break contacts with 2 instantaneous contacts and 2 delayed contacts on pull-in fully programmable (with dipswitch) from 0.5 seconds to 4 seconds. The access to dip switch is available by removing time delay cover. This feature prohibits frivolous field time delay setting. The plug-in design offers secure locking feature for maximum ease of maintenance (no wires need to be disconnected or other…
  • TTBCR 200 relay – Delay on drop-out, instantaneous

    The TTBCR 200 time delay relay has 2 changeover simple break contacts with 1 instantaneous contacts and 1 delayed contacts on drop-out fully programmable (with dipswitch) from 0.5 seconds to 4 seconds. The access to dip switch is available by removing time delay cover. This feature prohibits frivolous field time delay setting. The plug-in design offers secure locking feature for maximum ease of maintenance (no wires need to be disconnected…
  • TTBCR 400 relay – Delay on drop out instantaneous

    The TTBCR 400 time delay relay has 4 changeover simple break contacts with 2 instantaneous contacts and 2 delayed contacts on drop-out fully programmable (with dipswitch) from 0.5 to 4 seconds. The access to dip switch is available by removing time delay cover. This feature prohibits frivolous field time delay setting. The plug-in design offers secure locking feature for maximum ease of maintenance (no wires need to be disconnected or…
  • UB 003 relay – 3 Level load shedding

    The voltage monitoring relay UB 003 opens auxiliary loads circuits when battery voltage becomes too low and puts them back in service when battery voltage recovers. A time delay of 20 seconds engages before opening a load circuit and a time delay of 2 seconds before putting back in service a load. The plug-in design offers secure locking feature for maximum ease of maintenance (no wires need to be disconnected…
  • UB 200 relay – Voltage monitoring

    The voltage monitoring relay UB 200 opens auxiliary loads circuits when battery voltage becomes too low and puts them back in service when battery voltage recovers. A time delay of several seconds (to be defined) engages before opening a load circuit and a time delay of several seconds (to be defined) before putting back in service a load. The plug-in design offers secure locking feature for maximum ease of maintenance…
  • UB A400 relay – Voltage monitoring

    The voltage monitoring relay UB A400 opens auxiliary loads circuits when battery voltage becomes too low and puts them back in service when battery voltage recovers. A time delay of 20 seconds engages before opening a load circuit and a time delay of 2 seconds before putting back in service a load. The plug-in design offers secure locking feature for maximum ease of maintenance (no wires need to be disconnected…
  • UB C200 relay – Voltage monitoring

    The voltage monitoring relay UB C200 opens auxiliary loads circuits when battery voltage becomes too low and puts them back in service when battery voltage recovers. A time delay of several seconds (to be defined) engages before opening a load circuit and a time delay of several seconds (to be defined) before putting back in service a load. The plug-in design offers secure locking feature for maximum ease of maintenance…