Railway

  • QTA2 – immume DC neutral track relay

    The relays covered by this specification (see downloads) are for use on railways electrified on the 50 Hz AC system. Mors Smitt Relays Modular plug in design Non weld contacts Silver and carbon impregnated with silver contact tips Proven reliability Low life cycle cost
  • QTD4 – slow to release delay units

    The TY370/GRP01 is used in safety critical applications where a delay is required between the opening of a control contact and the release of a normally energised slave relay. The slave relay is powered from the TY370/GRP01 and thus does not require a separate supply. The TY372 is used in applications where an operate delay longer than that achievable by slugging is required. Mors Smitt Relays Modular plug in design…
  • QTD5 – slow to operate relays

    The TY372 is used in applications where an operate delay longer than that achievable by slugging is required. Mors Smitt Relays Modular plug in design Non weld contacts Silver and carbon impregnated with silver contact tips Proven reliability Low life cycle cost
  • QUCX5 – AC lamp proving relays

    The relays covered by this data sheet are designed as lamp proving relays where the relay is connected in series with the primary winding of the lamp transformer. TY153/GRP08 has the 50V D.C. stick coil (A7-D7) connected externally in series with a front contact. Mors Smitt Relays Modular plug in design Non weld contacts Silver and carbon impregnated with silver contact tips Proven reliability Low life cycle cost
  • RC-19A relay – Current monitoring

    Current monitoring railway relay with one change-over contact. Suitable for AC currents. The input consists of a ring core saturation transformer: place the wire with current to monitor simply through the transformer. Ease of installation and high continuous overcurrent possible. Protection against short circuit and low impedance. The relay is also suitable for earthfault protection. Adjusting the pull-in current for lower values by multiple threading through the transformer. The construction…
  • RDA Resistor unit

    The RDA resistor module consists of a D-relay housing containing 4 electrically isolated resistors. This gives the possibility to use them in different electrical circuits. Housing has venting holes for optimimum temperature behaviour. The RDA can be plugged in into all D-U sockets. Maximum allowable power inside the housing is 5W. Benefits: Proven reliable long term availability easy to maintain low life cycle cost no maintenance (more…)
  • Relay Marshalling Box (RMB)

    The RMB solution: fast, flexible, compact and reliable. (more…)
  • RelayDoc

    The Mors Smitt RelayDoc is designed and customised to provide controlled auditable testing of customer specific BR930/Q-Style signalling relays in accordance with their original BRB design specifications. (more…)
  • Retrofit & replacement solutions

    Extending life expectancy by upgrading obsolete and outdated rail network installations is mandating the replacement and retrofit of obsolete components. Many authorities recognize Mors Smitt´s expertise in this field, especially for retrofit and replacement with form, fit and function compliant systems (FFF). This is an area of increasing significance: Inhouse design and prototyping of new solutions Customer specific type testing and validation On site implementation and commissioning After sales support…
  • SB relay – Latching, 4/3 contacts

    The SB is a latching safety critical relay with 2 stable magnetically latched states. When 1 coil is energized, the relay actuates from magnetically latched position 1 to 2. When the other coil is energized, the relay actuates back from magnetically latched position 2 to 1. (more…)
  • SBG relay – Latching, 4/3 gold contacts

    The SBG is a latching safety critical relay with 2 stable magnetically latched states. When 1 coil is energized, the relay actuates from magnetically latched position 1 to 2. When the other coil is energized, the relay actuates back from magnetically latched position 2 to 1. (more…)
  • SC relay – Latching, 8 contacts

    The SC is a latching relay with 2 stable magnetically latched states. When 1 coil is energized, the relay actuates from magnetically latched position 1 to 2. When the other coil is energized, the relay actuates back from magnetically latched position 2 to 1. Relays have 8 double break contacts with different configurations. The plug-in design offers secure locking feature for maximum ease of maintenance (no wires need to be…
  • Smart Relay Monitoring System

    Railcar builders have been using relays to control equipment for years. During train maintenance, relays and devices such as lamps, door push-buttons or else are often exchanged before their end of life or when they are no longer working. Moving from schedule-based to condition-based maintenance saves significant maintenance costs for train operators. Mors Smitt™ smart Relay Monitoring System is developed to analyze the condition of relays and connected devices in real-time…
  • T2CBBU 400 relay – Asymetrical flasher, 4 contacts

    The T2CBBU 400 is an asymetrical flasher relay with 4 double make / double break C/O contacts (form Z). The first period is adjusted 0.1 s...1.5 s and second period 1 s...15 s. Time delay is achieved by combination of relay dip switch The access to dip switch is available by removing time delay cover. This feature prohibits frivolous field time delay setting. Timing can be also be factory set…
  • T2CBLBU 400 relay – Asymetrical flasher, 4 contacts

    The T2CBLBU 400 is an asymetrical flasher relay with 4 double make / double break C/O contacts (form Z). The first period is adjusted 0.1 s...1.5 s and second period 1 s...150 s. Time delay is achieved by combination of relay dip switch The access to dip switch is available by removing time delay cover. This feature prohibits frivolous field time delay setting. Timing can be also be factory set…
  • T2PBAU 400 relay – Two-shot time delay

    The T2PBAU 400 is a two-shot time delay relay with 4 double make / double break C/O contacts (form Z). The shots are triggered by the up and down front of the command input. The delay is fully programmable with a dip switch from 0.25 s to 63 min. The access to dip switch is available by removing time delay cover. This feature prohibits frivolous field time delay setting. The…