Mors Smitt hall effect closed loop sensors ensure high accuracy of current measuring in power electronics equipments for a full protection against overload or underload, control and regulation of the power equipment.

  • MSA 1005-S, 1000 A

    Closed loop Industrial applications, current measuring of all waveforms AC, DC. Chassis mount Closed loop High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault losses in the magnetic circuit Electrical specifications Primary nominal RMS voltage VPN 1000 A Primary voltage measuring range VP ± 1500 A Output measuring resistance RM 7 Ω max @ 15 V 70 °C 25 Ω max @ 24 V 70 °C Secondary…
  • MSA 2005-S, 2000 A

    Closed loop Industrial applications, current measuring of all waveforms AC, DC. Chassis mount Closed loop High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault losses in the magnetic circuit Electrical specifications Primary nominal RMS voltage VPN 2000 A Primary voltage measuring range VP ± 3000 A Output measuring resistance RM 11 Ω max @ 24 V 70 °C Secondary nominal RMS curent ISN 400 mA Conversion ratio…
  • MSA 305-S, 300 A

    Closed loop Industrial applications, current measuring of all waveforms AC, DC. Chassis mount Closed loop High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault losses in the magnetic circuit Electrical specifications Primary nominal RMS voltage VPN 300 A Primary voltage measuring range VP ± 300 A Output measuring resistance RM 20 Ω max for 500 A @ 15 V 70 °C 54 Ω max for 500 A…
  • MSA 505-S, 500 A

    Closed loop Industrial applications, current measuring of all waveforms AC, DC. Chassis mount Closed loop High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault losses in the magnetic circuit Electrical specifications Primary nominal RMS voltage VPN 500 A Primary voltage measuring range VP ± 800 A Output measuring resistance RM 7 Ω max for 800 A @ 15 V 70 °C 60 Ω max for 800 A…
  • MSV 100 – 950 V

    Closed loop Industrial applications, voltage measuring of all waveforms AC, DC Chassis mount Closed loop (compensated) High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault losses in the magnetic circuit EMC shielding (optional) Electrical specifications Primary nominal RMS voltage VPN 950 A Primary voltage measuring range VP ± 4000 A Output measuring resistance RM 220 Ω max for 1400 V @ 24 V 70 °C Secondary nominal RMS…
  • MSV 200

    Closed loop Industrial applications, voltage measuring of all waveforms AC, DC Chassis mount Closed loop (compensated) High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault losses in the magnetic circuit EMC shielding (optional) Electrical specifications Primary nominal RMS voltage VPN 1000 V / 2000 V / 3000 V / 4000 V / 5000 V Primary voltage measuring range VP ± 1500 V / ± 3000 V /…