Industry

  • MSA 1005-S, 1000 A

    Closed loop Industrial applications, current measuring of all waveforms AC, DC. Chassis mount Closed loop High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault losses in the magnetic circuit Electrical specifications Primary nominal RMS voltage VPN 1000 A Primary voltage measuring range VP ± 1500 A Output measuring resistance RM 7 Ω max @ 15 V 70 °C 25 Ω max @ 24 V 70 °C Secondary…
  • MSA 2005-S, 2000 A

    Closed loop Industrial applications, current measuring of all waveforms AC, DC. Chassis mount Closed loop High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault losses in the magnetic circuit Electrical specifications Primary nominal RMS voltage VPN 2000 A Primary voltage measuring range VP ± 3000 A Output measuring resistance RM 11 Ω max @ 24 V 70 °C Secondary nominal RMS curent ISN 400 mA Conversion ratio…
  • MSA 305-S, 300 A

    Closed loop Industrial applications, current measuring of all waveforms AC, DC. Chassis mount Closed loop High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault losses in the magnetic circuit Electrical specifications Primary nominal RMS voltage VPN 300 A Primary voltage measuring range VP ± 300 A Output measuring resistance RM 20 Ω max for 500 A @ 15 V 70 °C 54 Ω max for 500 A…
  • MSA 505-S, 500 A

    Closed loop Industrial applications, current measuring of all waveforms AC, DC. Chassis mount Closed loop High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault losses in the magnetic circuit Electrical specifications Primary nominal RMS voltage VPN 500 A Primary voltage measuring range VP ± 800 A Output measuring resistance RM 7 Ω max for 800 A @ 15 V 70 °C 60 Ω max for 800 A…
  • MSV 100 – 950 V

    Closed loop Industrial applications, voltage measuring of all waveforms AC, DC Chassis mount Closed loop (compensated) High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault losses in the magnetic circuit EMC shielding (optional) Electrical specifications Primary nominal RMS voltage VPN 950 A Primary voltage measuring range VP ± 4000 A Output measuring resistance RM 220 Ω max for 1400 V @ 24 V 70 °C Secondary nominal RMS…
  • MSV 200

    Closed loop Industrial applications, voltage measuring of all waveforms AC, DC Chassis mount Closed loop (compensated) High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault losses in the magnetic circuit EMC shielding (optional) Electrical specifications Primary nominal RMS voltage VPN 1000 V / 2000 V / 3000 V / 4000 V / 5000 V Primary voltage measuring range VP ± 1500 V / ± 3000 V /…
  • MTDV4 relay – Voltage monitoring, timer delay-on -off, 4 pole

    Plug-in electronic voltage monitoring relay with optional delay-on and delay-off timer function and four change-over contacts. The delay time is adjustable with a lockable knob (either delay-on or delay-off, the other delay is fixed). The relay can also be supplied with fixed time delays (no knob). The pull-in voltage and drop-out voltage are both adjustable via internal screws. The relay can also be supplied with a fixed pull-in and drop-out…
  • Multimeter – basic set

    This practical basic set makes it safe voltage and current are measured. This set consists of: NI 64 multimeter (click here) EazyVolt Basic voltage tester (click here) NI T38 current clamp adapter (click here) Ordering code: 626000864
  • Multimeter bag large

    Multimeter bag large Ordering code: 626006052
  • Multimeter bag small

    Multimeter bag small Ordering code: 626006051
  • Neckstrap – Instaltest XB

    Neckstrap - Instaltest XB Ordering code: 626001107
  • NI 10R Compact Clamp

    The NI 10R is an ergonomically shaped clamp meter. It is suitable for measuring AC and DC currents (up to 400 A), AC and DC voltages, resistances, capacitance and frequencies. The temperature can also be measured. The measured value is clearly displayed on the LCD display. Characteristics True RMS AC/DC voltage AC/DC current Resistance, Capacitance and Frequency Measurement Passage Temperature Display hold Specifications Functions Maximum range Accuracy Voltage 600 VAC…
  • NI 14R Complete current clamp

    The complete and versatile current clamp NI 14R is an elegant and ergonomic shaped instrument.   (more…)
  • NI 19 Plus Current Clamp

    The NI 19PLUS is a sturdy, high quality multifunctional True RMS current clamp. The clamp can measure up to 600 AAC/DC and 1000 VAC/VDC. Other functionalities like power factor, power (Watt) and phase rotation complete the NI 19PLUS as the most allround clamp in the range. The fact that the NI 19PLUS can measure both AC and DC power, makes the clamp very suitable for measuring solar PV-systems. In combination with the EazyFlex…
  • NI 333 Earth leakage clamp

    At first, the NI 333 looks like a normal current clamp. Nevertheless, the special integrated technique of the jaw enables the user to measure very low or differential currents. The NI 333 is designed with an ergonomic housing with a wide jaw (opening). With this jaw, conductors up to 30 mm can be measured easily. The jaw of the clamp is very sensitive, yet very well isolated. This enables the…
  • NI 407 plus, multimeter with insulation measurement

    Waterproof CAT IV multimeter with insulation measurement The sturdy and waterproof (IP67) NI 407PLUS is a True RMS multimeter with built-in insulation resistance and earth bound tester. Allows the insulation resistance to be measured with 5 different test voltages for measuring up to 5 GΩ. The meter can measure the earth bound with 200 mA according the applicable EN 61557-4 standard The NI 405PLUS includes useful extras such as duty…