Description
Round panelindicator for railway applications, single pointer.
General specifications
Accuracy
1.5 % F.S.D.
0.75 % / 10 °C
Operating temperature
-25 °C…+70 °C
Humidity
at 40 °C max 95 %
Protection
Front IP54
Rear IP50 (terminals IP00)
Vibrations
5…150 Hz, 2 g random 3 x 5 h acc. EN 61373 (50155)
Shock
According to EN 61373
Test voltage
2 kV
Illumination
LEDS, Any voltage between 24 V and 110 VAC/VDC
Scale and pointer
Black scale, white pointer and figures
Terminals
Movement: M5, illumination : faston 6.3 x 0.8
Glass
Low reflection
Panel mounting
With one bracket, panel cutout 80.5 mm
International standards
IEC 571
EN 60051
EN 50155
EN 50121
Movement signal
0 … 20 mA
4 … 20 mA
0 … 2.5 mA
0 … 10 V
other inputs on request
zero left or middle
Codes
B : acc. EN 50155 (standard)
W : White scale
Options
White scale with black pointer and printing
Pointer yellow or red
Brand label on scale
Red line marlin(s) on the scale
Couloured band(s) on the scale